Difference between revisions of "Talk:DEWBOT XII Mid-Atlantic Robotics District Championship"
From DEW Robotics
MaiKangWei (talk | contribs) |
MaiKangWei (talk | contribs) |
||
Line 9: | Line 9: | ||
And the CBA III performance charts: | And the CBA III performance charts: | ||
− | [[image:CBA_III_graph.jpg|450px| | + | [[image:CBA_III_graph.jpg|450px|left]] |
+ | |||
+ | Three batteries were removed from service as a result of the testing: AD, AE & AF. Note that AC had previously been removed from service. | ||
---- | ---- | ||
[[Category:DEWBOT XII]] | [[Category:DEWBOT XII]] |
Revision as of 12:36, 24 April 2016
Post-Mortem
Battery Testing
In spite of the fact that we test all batteries with a Battery Beak before competition, we had a battery failure at Westtown (battery AD) and a more complete one at MAR Championship (battery AF) where we just managed to crawl to the batter at the start of the match.
We tested all competition-rated batteries 18-20 April using the CBA (Computerized Battery Analyzer) III by Optim Engineering (marketed and sold by West Mountain Radio).
The data collected on the batteries is here:And the CBA III performance charts:
Three batteries were removed from service as a result of the testing: AD, AE & AF. Note that AC had previously been removed from service.