STATUS LED | LED State Module Status |
---|---|
Normal Operating Conditions | |
Solid Yellow Neutral | (speed set to 0) |
Fast Flashing Green | Forward |
Fast Flashing Red | Reverse |
Solid Green | Full-speed forward |
Solid Red | Full-speed reverse |
Fault Conditions | |
Slow Flashing Yellow | Loss of servo link |
Slow Flashing Red | Fault condition |
Calibration Conditions | |
Fast Flashing Red and Green | Calibration mode active |
Fast Flashing Red and Yellow | Calibration mode failure |
Fast Flashing Green and Yellow | Calibration mode success |
Slow Flashing Red and Green | Calibration mode reset to factory default settings success |
To calibrate the servo-style PWM input for a specific range, connect a PWM source, then:
1. Hold down the USER switch with a straightened paperclip.
2. After 5 seconds, the LED flashes Red and Green quickly to indicate Calibration mode.
3. Instruct the controller to send a full-forward signal.
4. Instruct the controller to send a full-reverse signal.
5. Instruct the controller to return to a neutral signal.
6. The LED flashes Green and Yellow quickly to indicate a successful calibration.
7. Release the USER switch.
The MDL-BDC samples these signals and centers the speed range and neutral position between these limits. A calibration failure will be signaled if an out-of-range signal is detected. To reset the servo-style PWM input to the default factory range:
1. Disconnect the power to the MDL-BDC.
2. Hold down the USER switch with a straightened paperclip.
3. Reconnect power to the MDL-BDC
4. After 5 seconds, the LED flashes Red and Green slowly to indicate a successful calibration reset to factory settings.
5. Release the USER switch.